This is
a new product for industrial users. It is an electronic control
unit based on the OMRON industrial control system used to
control electronic ECOGATE® blast gates . In connection
with the Inverter, it continually optimizes the amount of
power supplied to your dust collector. That generates savings.
|
| |
Standard
version has 22 channels (EG102a), the other versions 44
(EG102b) and 88 (EG102e) channels (a channel means output
for the blast gate and input for the sensor). Each
channel can control up to six blast gates working in parallel
(this feature is important on multi-port machinery) and
one sensor. |
|
  |
| |
- Automatic
or manual bypass and test control modes.
- Fully
automatic regulating loops to ensure necessary air
velocity and vacuum level using the minimum of the
dust collector power.
|
| SPECIFICATIONS |
|
MODEL
|
ECOGATE,
Part No. EG102a (b,e) |
|
CASE
|
Size:
approx. 24" x 24" x 11", dust proof
grounded metal box, green painted. |
|
WEIGHT
|
Approx.
62 Lb |
|
POWER
SUPPLY
|
230
V AC, 60Hz, 150W max. |
|
FUSE
|
Breaker
|
|
OPERATING
& STORAGE CONDITIONS
|
For
indoor use only (protected from corrosive gases).
Operating temperature: 23° F to 104° F
Operating humidity: 10% to 90% (non-condensing)
Storage temperature: 5° F to 140° F
Storage humidity: 10% to 90% (non-condensing) |
| LOW-VOLTAGE
INPUTS/OUTPUTS |
Model
a: 24V DC, 22x Input/Output channels for blast gates
and sensors, Screw Terminal Blocks, 16 AWG (1.5
mm_), serial output for Power MASTER unit, serial
connection for PC, other models (b, c) available
with more input/output channels |
| FRONT
PANEL DISPLAY |
LCD
monochrome touch screen, 7" x 4", displays
actual dust collector power, gates that are open,
actual savings, vacuum level |
INTERNAL
SETUP ELEMENTS
(password protected) |
a/
blast gate "RUN TIME" (1-4.8 sec. selectable
by software), individually adjustable for every
channel, b/ "DUST COLLECTOR OFF DELAY TIME"
(0 to 25 minutes selectable by software), c/ "BLAST
GATES TO REMAIN OPEN" (for cyclone units, to
maintain minimum airflow), d/ "SENSOR ON SENSITIVITY"
, e/ "SENSOR OFF SENSITIVITY" ,
f/ "CHANNEL ENABLE/DISSABLE" |
| SENSOR
TYPE |
ECOde
/i industrial sensor which reads AC current to the
machine motor |

About
the System The
Products CFM
Demand Project
Work List How
Much Can You Save?
FAQ's
Additional Resources
Information Request
Contact Us
Copyright
© 2001 EnergyEcon
Please read our Privacy
Statement
|
|
|